Main menu:
Note: Actual frequency of operation is within the listed frequency range, with the specified bandwidth applied. All devices are made to order, with performance optimised over your specified frequency range. Extended operating temperature ranges are available. Please contact our sales department for details.
Type No. |
Frequency |
B/W |
Fwd Loss |
Isolation |
VSWR |
OTR |
Power W |
Flange |
Size mm |
WG10 |
2.6 - |
0.5 |
0.2 |
23 |
1.15:1 |
- |
1kW/20kW |
CPR284F |
|
WG11A |
3.3 - |
0.5 |
0.2 |
23 |
1.15:1 |
- |
1kW/20kW |
CPR229F |
125 x 135 x 70 |
WG12 |
3.94 - |
0.75 |
0.2 |
23 |
1.15:1 |
- |
1kW/20kW |
UDR48 |
100 x 105 x 92 |
5.38 - |
1.0 |
0.2 |
25 |
1.15:1 |
- |
750W/15kW |
CPR137F |
95 X 97 X 49 |
|
P- |
6.58 - |
1.5 |
0.2 |
25 |
1.15:1 |
- |
500W/15kW |
UBR84 |
70 x 69 x 48 |
8.2 - |
2.0 |
0.2 |
25 |
1.15:1 |
- |
500W/10kW |
UBR100 |
41 x 51 x 41 |
|
8.5 - |
1.1 |
0.25 |
20 |
1.2:1 |
- |
750W/50kW |
UBR100 |
51 x 51 x 51 |
|
9.84 - |
3.0 |
0.2 |
23 |
1.15:1 |
- |
400W/10kW |
UBR120 |
45 x 45 x 38 |
|
11.9 - |
2.0 |
0.2 |
23 |
1.15:1 |
- |
250W/5kW |
UBR140 |
40 x 45 x 34 |
|
WG20 |
17.6 - |
1.0 |
0.2 |
23 |
1.15:1 |
- |
150W/5kW |
UBR220 |
30 x 30 x 23 |
Note: Finish for the above items has been changed to SurTec 650 (hexa-